The European Union is
generally ahead of the North America in restricting toxic substances in
electronic products. Their latest restrictions, known as RoHS (Restriction
of Hazardous Substances), went into effect in July
2006.
The backdrop to the introduction of RoHS was one of increasing
environmental regulations worldwide and increasing concern for human health and
safety and ecosystems around the world. Hazardous
chemicals in products were fast becoming a health and environmental concern.
We are dedicated to
developing innovative design solutions that maximize the function and value
of our products while minimizing the impact on the environment. These
efforts include careful selection of materials to ensure product quality
while making it
easier for consumers to recycle materials at the end of a product's
functional life.
Azel Technologies is committed to
meeting the requirements of the European Union Directive on RoHS in our
products.The RoHS
directive restricts the presence of certain substances including lead,
hexavalent chromium, mercury, cadmium and two brominated flame retardants -
polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE).
Through design choice and substitution, we've continually avoided or
eliminated the use of certain materials of concern in our products.
. DST
SERIES (DST-777S, DST-777D, DST-7772) DIGITAL SETPOINT TEMPERATURE
CONTROLS
DST-777 series controls
are microprocessor-based electronic one or two stage setpoint temperature
controls, designed to provide one or two on/off controls (Single-Pole
Double-Throw(SPDT) relay output) for residential/commercial heating, cooling,
air conditioning and refrigeration applications.
The DST-777 is equipped with a Dual Digital
display with backlit that provides a constant readout of the sensor temperature
and setpoint simultaneously as well as the other programmed settings. The front
buttons allow the user to easily and accurately select the set point
temperature, differential and heating/cooling mode of the operation. Unique
QuickSet feature allows instant setpoint adjustment without entering programming
mode. This reliable and versatile control has a very wide setpoint range, an
adjustable differential and time delay that makes it applicable in many
different applications. The single stage models have
Pulse Width Modulation (PWM) control logic to prevent overshoots and
undershoots in slow responding systems with large thermal mass such as pools or
slabs. A sensor probe P-01 is supplied with the control. This solid state
temperature sensor probe can be extended up to 500 feet.
APPLICATIONS:
The DST series can be used for a
wide variety of applications:
-
Slab thermostat for radiant floor heating
-
Tank Heating
-
Boiler control (used as a thermostat)
-
Space and return air temperature control
-
Condenser fan cycling
-
Milk coolers
-
Cooling tower pump control
-
Refrigerated warehouses
-
Chillers
-
Beer and beverage coolers
-
Refrigerated display cases
-
Walk-in and reach-in refrigerators
-
Other applications: research, science, laboratory,
education, aquarium, hydroponics, pools and more
Pulse Width Modulation (PWM)
The single stage models (DST-777S, DST-777D)
offer optimum control by means of a Pulse Width Modulation. The ON and OFF cycle
vary depending on the difference between the sensor and setpoint temperature.
The bigger difference between the sensor and setpoint temperature, the longer
the relay is switched ON. When the sensor temperature approaches the setpoint
temperature, the ON time become shorter and shorter. Pulse Width Modulation
guarantees precise control response. This function prevents overshoots and
undershoots in systems with large thermal mass (eg. slabs or pools).
DST-777 SINGLE
STAGE AND TWO STAGES DIGITAL SETPOINT TEMPERATURE CONTROL
  
Please click to view PDF Brochure
DST-777S/DST-777D PDF Installation Instructions
DST-7772 PDF Installation
Instructions
FEATURES:
-
Reliable Digital Electronic Accuracy
-
QuickSet feature allows instant setpoint adjustment without
entering programming mode
-
Easy-to-Read Dual Digital Display with backlit which displays
sensor temperature and setpoint simultaneously, functional status and
control settings. It also allows precise setpoint and differential settings
-
Simple and user-friendly programming of setpoint temperature,
differential and cooling/heating modes
-
EEPROM memory retains control settings in the event of a
power failure
-
Wide adjustable setpoint with temperature range from -40 to
240°F and differential from 1 to 100°F. This enables the user to optimize
the system performance for any applications. A tighter differential can be
achieved (eg. 1°F or 1°C) than conventional electro mechanical controls
-
Advanced PWM (Pulse Width Modulation) Control to achieve high
control accuracy on single stage models
-
Fast sampling rate (once/second) of the sensor temperature
for instant control action
-
Choice of one or two stage models
-
One or two SPDT relay outputs. Model: DST-7772(two stage) can
handle one or two sensor inputs with two setpoints. When using two sensor
inputs, each setpoint can be corresponding to one relay output. (Two units
in one control)
-
LED indicates output relay status
-
Adjustable Anti-Short Cycle Delay to ensure the output relay
remains off for up to 20 minutes. This would avoid unnecessary hard start
and equipment wear
-
Selectable Fahrenheit or Celsius scales
-
Selectable Heat or Cool modes
-
Maximum and minimum memory for sensor temperature
-
Lockout switch to prevent tempering by unauthorized personnel
-
Remote temperature sensor which can be extended to 500 ft.
-
Sensor failure and out of range indication
-
Easy installation and setup
-
Easy-Connect Screwless Terminals for sensor connection
-
Backlit option: Auto (30 sec.)/OFF/ON
-
Power surge protection
SPECIFICATIONS:
-
Setpoint Temperature Range: -40 to 240°F(-40 to 116°C)
-
Temperature Display Resolution: 0.1°F/0.1°C
-
Differential Adjustment: 1 to 100°F(1 to 38°C)
-
Anti-Short Cycle Delay: 0 to 20 min. (1-Minute increments)
-
PWM Cycle Length: 30 to 1500 sec. (10-Second Increments)
-
PWM Differential: 3 to 50°F (2 to 25°C)
-
Accuracy: ±1°C / ±1°F
-
Input: 10K ohm thermistor probe(included): P-01 (designed for
strap on a pipe or insert into a temperature well)
-
Operating Voltage: 120 or 240 VAC, 50/60Hz
-
Temperature sampling rate: once/sec.
-
Relay: 1 or 2 x SPDT, 120VAC, Full Load 10A, 1Hp
-
Enclosure: Flame Retardant Plastic 94V0
-
Weight: 3.0 lbs
-
Dimension: 6 3/8”(W) x 6 5/8”(H) x 2 3/4”(D)
UNIVERSAL DIGITAL SETPOINT TEMPERATURE CONTROLS
DST-900 - ONE STAGE * DST-922 - TWO STAGE

Please
click to view PDF Brochure
DST-900/902/922
PDF Installation Instructions
DST series was
conceived on purpose to be installed on switchboards, panel boards,
heating/cooling units and other applications.
FEATURES:
-
Reliable Digital Electronic Accuracy
-
Easy-to-Read Digital Display
which displays sensor temperature and functional status. It also allows
precise setpoint and differential settings
-
Simple programming of
setpoint temperature, differential and cooling/heating modes. Setpoint can
be adjusted easily wihout going into programming mode.
-
Wide adjustable setpoint
with temperature range from -39 to 248°F ( -39 to 120°C) and differential
from 0 to 18°F (0 to 10°C). This enables the user to optimize the system
performance for any applications. A tighter differential can be achieved
(eg. 1F or 1C) than conventional electromechanical controls
-
Anti-Short Cycle Delay to
ensure the output relay remains off for up to 254 secs. This would avoid
unnecessary hard start and equipment wear
-
Cooling applications include
automatic defrost timing as well as manual defrost
-
User selectable Celsius or
Fahrenheit scales

-
Adjustable temperature
offset to compensate any deviation from the real temperature value
-
Selectable decimal point or
unit resolution
-
Lockout switch to prevent
tempering by unauthorized personnel
-
A universal 10K ohm sensor P-01 is supplied
with the control. This solid state temperature sensor probe can be extended
up to 500 feet.
-
Easy installation
SPECIFICATIONS:
-
Setpoint range:-39 to 248°F
( -39 to 120°C)
-
Differential: 0 to 18°F(0 to
10°C)
-
Anit Cycling Delay: 0 to 254
sec.
-
Output: 1 SPDT 250VAC 16A
max resistive (1HP), + 1 SPDT 250VAC 8A max resistive (0.5HP) only for
DST-922
-
Resolution: 0.1°C (0.2°F) or
1°C (1 or 2°F)
-
Accuracy: ± 1°F
-
Display: High intensity
Green LED, 3 digits, 13.2 mm
-
Data storing: on EEP-ROM not
volatile memory
-
Operating temperature: 23 to
122 °F (-5 to +50 °C)
-
Sensor Probe: Model: P-01,
10K ohm NTC (included)
-
Relative humidity: 30 to 90
% (not condensing)
-
Power supply: 115VAC ± 10%,
50/60Hz
DST-900PR/DST902PR/DST-922PR (DIN Rail
models)
-
Housing: self-extinguish
UL94V0 ABS plastics, white colour
-
Size: frontal 45 x 71 mm;
depth 58 mm (4 DIN modules)
-
Mounting: DIN rail for panel
boards
DST-900E/DST902E/DST-922E (Aluminium
Enclosure models)
-
Housing: premium quality
aluminium enclosure with blue powder coat cover
-
Size: 8" x 4" x 2"
-
Included dual row terminal
block for universal wiring needs
i-Link SERIES ZONE CONTROLS (
SWITCHING RELAYS ) FOR HYDRONIC HEATING ( RADIANT FLOOR HEATING ) SYSTEMS

A NEW ERA IN ZONE CONTROLS...
The
i-Link series multi-zone circulator switching relays simplify wiring for
hydronic heating ( radiant floor heating ) systems. With leading edge features
and superior product design, i-Link makes installation quick and easy.
Available in one to six zone models. The i-Link series are designed with
flexibility and multi-zone applications in mind. It is so flexible that
different models can be interconnected for unlimited zone expansion. In
addition, i-Link provides far more functional status than other models on the
market today because of their front panel LED indicators that provide the easy
system diagnostics demanded by today’s installers. Each unit is designed with a
unique power surge protection to ensure continuous control operation and avoid
damage and trouble to replace the unit.
Selectable Priority with Protection Timer
Priority Protection timer available in two to six zone models prevents
freeze-ups in the event of a priority zone failure. SP-84, SP-85, SP-86 are
equipped with field selectable priority by-pass function to ensure continuous
operation of secondary zones which allow maximum flexibility for system
applications.
From design to manufacture, each i-Link unit is built on
the foundations of quality and reliability. Azel products are quality controlled
in order to achieve “total customer satisfaction” - a foundation that you can
rely on.
GENERAL
FEATURES:
-
Front panel indicator lights
-
Fuse protection
-
Power surge protection
-
Easy-Connect Terminals/Screwless Terminals for Thermostat
Connections
-
Compact and modern design
-
Safety design with all electronic components hiding behind
the enclosure
-
Simplified wiring
-
Universal Design: Cold Start or Tankless Coil Boiler
-
Contractor friendly PCB layout
-
High Capacity Transformer
-
24VAC transformer output with common terminal provides
compatibility with electronic thermostat
-
Universal thermostat compatibility
-
100% Factory Tested
-
Extended 3 year warranty
ADDITIONAL
FEATURES(SP-82 TO SP-86):
-
Unlimited zone expansion
-
Priority timer for protection of a priority zone malfunction
and prevention of freeze-ups in the heating zones
-
Field selectable priority
-
Capable of turning on extra system circulator
-
SP-84/85/86: Manual priority override(bypass) for each of the
secondary zone
-
Isolated End Switch
  
 
SPECIFICATIONS:
| Model:
|
SP-81 |
1 Zone Switching
Relay |
| |
SP-82 |
2
Zone Switching Relay |
| |
SP-83 |
3 Zone Switching
Relay |
| |
SP-84 |
4 Zone Switching
Relay |
| |
SP-85 |
5 Zone Switching
Relay |
| |
SP-86 |
6 Zone Switching
Relay |
| Power Supply: |
|
120 VAC, 50/60Hz |
| Dimensions: |
|
6 3/8”(W) x 6
5/8”(H) x 2 3/4”(D) |
| Electrical Switch Rating: |
|
10 A 1/3 HP @ 120VAC |
| Thermostat Anticipator
Setting: |
|
0.18 A |
| Enclosure: |
|
Flame Retardant
Plastic 94V0 |
| Shipping Weight:
|
|
SP-81/82/83 3 lbs;
SP-84/85/86 4 lbs. |
  
Please click to
view PDF Brochure
SP-81 PDF
Installation Instructions
SP-82 to SP-86
PDF Installation Instructions
i-Link SERIES ZONE VALVE
CONTROLS FOR HYDRONIC HEATING ( RADIANT FLOOR HEATING ) SYSTEMS
The i-Link series Zone Valve Controls simplify the field wiring and yet
control up to six zone valves in a multi-zone hydronic heating system.
The contractor friendly Printed Circuit Board eliminates the problem
caused by incorrect wiring and saves hours of installation time. There
would be no more “messy” look of conventional zone valve installations.
Intelligent Linking System (i-Link) allows unlimited zone expansion with
additional i-Link controllers. Field selectable priority with Priority
Protection Timer ensures other zones get heat every one hour and
prevents freeze-ups in the event of a priority zone failure. The End
Switch delay timer let the two wire type zone valves fully opened before
turning on the circulator. The panel provides EZ screwless terminal
blocks for connections to the thermostats and zone valves. In addition,
LED indicators on the front panel provide functional status and easy
troubleshooting.
GENERAL
FEATURES:

-
Front panel indicator lights
-
Field selectable Priority
-
Priority timer for protection of a priority zone
malfunction and prevention of freeze-ups in the heating zones
-
Unlimited zone expansion
-
Dual Isolated End Switches for SZ-84/86DX
-
Three-minute End Switch delay timer for two wire type
zone valve applications. Circulator will start only after the zone
valve is fully opened.
-
DIP switch for easy setup of two wire type zone valve
applications. No need to hook up wire jumper on the third and fourth
terminals on each zone
-
Works with two, three or four wire type zone valves
and thermostats
-
Compact and modern design
-
Safety design with all electronic components hiding
behind the enclosure for SZ-84/86DX
-
Fuse protection
-
Simplified wiring
-
Contractor friendly PCB layout
-
Easy-Connect Screwless Terminals
-
24VAC transformer output with common terminal
provides compatibility with electronic thermostats
-
Universal thermostat compatibility
-
100% Factory Tested
-
Extended three year warranty
ADDITIONAL FEATURES FOR SZ-V4/SZ-V6

-
Isolated End Switch
-
Pre-wired terminals for circulator
-
SPDT Priority zone relay switch (N/O Com N/C).
Capable of prioritizing DHW pump in a 2-pump system
-
50VA replaceable transformer
SPECIFICATIONS:
|
Model:
|
SZ-84DX |
4 Zone
Valve Control |
| |
SZ-86DX |
6 Zone Valve
Control |
| Power
Supply: |
|
24
VAC, 50/60Hz |
|
Dimensions: |
|
6
3/8”(W) x 6 5/8”(H) x 2 3/4”(D) |
|
Electrical Switch Rating: |
|
10 A 1/3
HP @ 120VAC |
|
Thermostat Anticipator Setting: |
|
0.18 A |
|
Enclosure: |
|
Flame
Retardant Plastic 94V0 |
| Shipping Weight:
|
|
3 lbs |
|
Model:
|
SZ-V4 |
4 Zone
Valve Control with transformer |
| |
SZ-V6 |
6 Zone Valve
Control with transformer |
| Power
Supply: |
|
120
VAC, 50/60Hz |
|
Dimensions: |
|
11”(W)
x 6 5/8”(H) x 3”(D) |
|
Electrical Switch Rating: |
|
10 A 1/3
HP @ 120VAC |
|
Thermostat Anticipator Setting: |
|
0.18 A |
|
Enclosure: |
|
Aluminum
|
| Shipping Weight:
|
|
5
lbs |
  
Please click to view PDF Brochure
SZ-84/86DX PDF Installation
Instructions
SZ-V4/V6 PDF Installation Instructions
DIGIT-STAT DS-60 DIGITAL TEMPERATURE GAUGE FOR
HYDRONIC HEATING/SOLAR HEATING/GEOTHERMAL SYSTEM

Please
click to view PDF Brochure
The microprocessor-based, AZEL Technologies
Digital Temperature gauge DS-60 represents the “next generation” in temperature
gauge industries. The bold, hi-contrast LCD display ensures accurate temperature
reading to the tenth degree and can be easily read from greater distances than
the typical mechanical temperature gauge.
DS-60 REPLACES TWO
mechanical temperature gauges as it can centralize the readings in one spot and
simultaneously display the accurate temperatures of supply and return piping on
a hydronic heating system. In addition, the solid state temperature sensor probe
can be extended up to several hundred feets. The unit is designed to be powered
by 24VAC input or by lithium battery. When 24VAC is supplied, the lithium
battery enable the unit to work in case of power failure. Its features also
include Min/Max memory which shows the highest and lowest temperature after the
last reset and instant Fahrenheit to Centigrade conversion. DS-60 is also ideal
for any application (EG. Solar heating or Geothermal) that requires quick and accurate response to temperature
change, an easy to read display and a wide temperature range.
FEATURES:
- Dual Large LCD (Liquid Crystal Display) to show
supply and return temperature
- Min/Max memory can be selected for both
OUT(Supply) and IN (Return) water temperature since the last time RESET button
was pressed.
- Celsius or Fahrenheit switch on the front unit.
- Dual Power input: 24VAC or Lithium Battery
(24VAC input has priority over Lithium Battery input if both power inputs are
applied)
- Easy installation
- Frequent sample rate dictate any change in
temperature instantly
SPECIFICATIONS:
- Display: Dual LCD (Liquid Crystal Display)
- Temperature range: -58F to 302F (-50C to 150C)
- Resolution: 0.1F(0.1C).
- Accuracy: ±1C / ±2F
- Sample rate: 3 Secs.
- Input: 2 x 10K ohm thermistor probe model: P-03
(designed for strap on a pipe or insert into a temperature well)
- Operating Voltage: 24VAC or Lithium Battery
(included, last for over 3 years)
- Size: 3.5” x 2.0” x 0.9” (88.9mm x 50.8mm x
22.86mm)
- Enclosure: Flame-retardant plastic
- Operating Temperature: 32 to 122F(0 to 50C)
- Weight: 0.11lbs (50g)
|
Universal Sensor Probe Model: P-01, P-03
The Azel Sensor Probe is engineered to ensure
long life and rapid response. It is designed to strap on a pipe or insert into a
temperature well. P-01 is specially designed for use with DST-900 and DST-777
series and other controls that require 10K ohm thermistors. P-03 is designed for
DS-60P.
SPECIFICATIONS:
- Sheath: Copper
- Lead: 10” of 20 AWG heat resistence wire
- Dimension: 3/8" OD x 13/16" length (9.5mm OD x
20.6mm)
- Weight: 0.02lb (10g)
- Operating range: -60 to 255F (-50 to 125C)
- Senor: 10K ohm @ 77F (25 C ± 1%) thermistor
- Measuring range: P-01:
-40 to 240°F(-40 to 116°C) for DST-900 & DST-777
series, P-03: -58 to 302°F(-50 to 150°C) for DS-60P only
NON-PROGRAMMABLE DIGITAL THERMOSTATS

D-135E
Please
click to view PDF Brochure

D-135ES
Please
click to view PDF Brochure
D-138
Please
click to view PDF Brochure
The D-135 series thermostat
is a stand-alone microprocessor based thermostat with large LCD display that
takes the guess work out of reading the temperature. The D-135 maintains highly
accurate temperature control without the programming hassle. The thermostat is
designed to control room temperature by way of on/off controlling the heating
(and cooling) equipments. The setpoint is displayed and can be changed easily by
pressing up or down arrow button. D-138 has a unique “spinning-switch” dial
allows instant setpoint change of ±3°F as quick as a flash. This simple to use
accurate thermostat will replace most round, square or rectangular thermostats.
D-135 is environmentally safe, mercury-free which requires no leveling, so
there’s no hassle, and no special disposal requirements.
FEATURES:
- Deluxe standard
Heat Only
- Reliable Digital Electronic Accuracy
- EEPROM (memory) for setting backup
- Adjustable differential setting
- Anti-short cycle delay
- On/Off switch (D-135ES)
- Heat icons displays when calling for heat
- Contains NO Mercury, environmentally safe
- Accurate Universal Replacement
- No Leveling Required
- Low Voltage (24 VAC) Systems
- Only 2 wires needed to power thermostat, no
need to change battery in the future
- Display in °F
- Modern design
- Built-in Digital Control System instantly
D-138 ADDITIONAL FEATURES:
- Unique “spinning-switch” dial allows instant setpoint
change of ±3°F as quick as a flash
- Fan Switch
- Heat/Cool/Off Switch
- EEPROM for Setting Backup
SPECIFICATIONS:
- Display Format: Liquid Crystal Display(LCD)
- Power Supply: 24 Vac, 50-60Hz
- Contact Rating: 7A Resistive (3A inductive)
- Sampling Rate: 1 Minute
- Accuracy: ±1°F
- Switch Differential: 0.5 to 2.0°F (D-138)
- Temperature Control Range: 40-95°F
Weight: 0.11lbs (50g)
NON-PROGRAMMABLE DIGITAL THERMOSTAT FOR RADIANT FLOOR HEATING
D-508F
 
Please click to
view PDF Brochure
Please click
to view PDF Instruction
D-508F digital
non-programmable heat only thermostat is designed to control either ambient(air)
temperature (A Mode) or floor temperature (F Mode) or a combination of ambient
temperature with floor temperature limits(AF Mode). An auxiliary remote sensor
is provided to measure slab temperature in order to control the floor
temperature(within maximum and minimum limits in AF Mode). It can also be used
for sensing the outdoor temperature in A Mode.
FEATURES:
- Easy-to-Read Digital Multi-Display with backlit which
provides constant readout of two sensor temperatures(eg. ambient and floor)
and setpoint simultaneously, functional status and control settings.
- Three temperature control modes:
A Mode : controls ambient temperature
F Mode : controls floor temperature. Also displays current ambient
temperature. AF Mode:
controls the ambient temperature and maintains the floor temperature within
the desired minimum limit for floor warming and maximum limit for protecting
floor coverings. Also, displays current floor temperature.
- QuickSet feature allows instant setpoint adjustment
without entering the SETTING mode
- Contemporary design
- Easy installation and setup
- Selectable display in °F or °C
- On/Off switch to shut off relay output or shutdown the
thermostat at end of heating season for added security
- EEPROM memory retains control settings in the event of a
power failure
- Lockout mode to prevent tempering by unauthorized
personnel
- Sensor failure and out of range indications
- One stage heating application
- Backlit option: Auto (60 sec.)/OFF/ON
- Supplied with P-01 floor sensor
- Battery free
- RoHS(Restriction of Hazardous Substances) compliant
means this thermostat is Eco- friendly
SPECIFICATIONS:
- Display Format: Liquid Crystal Display(LCD) with backlit
- Power Input : 24VAC ±10%, 50/60Hz, 0.5VA
- Contact Rating: 2A 24VAC
- Selectable display in °F or °C
- Setpoint Range (ambient): 34-100°F(1-38°C). Default
setting: 70°F (21°C)
- Floor Temperature Control Range: 34-122°F(1-50°C)
Default setting: 82°F (28°C)
- Maximum Floor Temperature Limit(AF Mode):
35-122°F(2-50°C) Default: 82°F(28°C)
- Minimum Floor Temperature Limit(AF Mode):
34-121°F(1-49°C)
Default: 40°F(5°C)
- Temperature Display Range: -22 to 131°F(-30 to 55°C)
- Switching Differential: A/F/AF Mode:
0.5/1.0/1.5/2°F(°C), Default: 1°F/1°C
- Sensor Probe: P-01 10kΩ thermistors, 10" lead,
3/8"(9.5mm) OD x 13/16"(20.6mm) length
- Operating Temperature: 32 - 122°F (0 - 50°C)
- Dimension: 3.62"W x 2.99"H x 0.91"D(92 x 76 x 23mm)
- Weight: 0.32 lb. (145 g)
- Storage: -4 to 120°F (-20 to 50°C)
- Material: Flame retardant plastic
D-28F
 
Please click to
view PDF Brochure
Please click to
view PDF Instruction
D-28F digital thermostat is specifically designed for
Radiant Floor Heating Systems. It is so flexible that it can be used to
control either air temperature (A Mode) or floor temperature (F Mode) or a
combination of air temperature with floor temperature limits(AF Mode). An
auxiliary remote sensor is provided to measure slab temperature in order to
control the floor temperature within desired maximum and minimum limits.
FEATURES:
- Large LCD display
- Dual sensor
control modes:
Mode A: Room sensor for Heating/Cooling.
Mode F: Floor sensor with maximum and minimum
limits Mode AF: Room
sensor and Floor sensor combined to control the ambient temperature and
maintains the floor temperature within the desired maximum limit
- Battery operated
- Large LCD display
- Freeze protection
- No Leveling Required
- Contains NO Mercury, environmentally safe
- Two wire type thermostat
- Selectable display in °F or °C
- EEPROM for setting backup
- ON/OFF switch to shut off relay output
- Supplied with 10ft. floor sensor
- Easy Comfort or Economy Setpoint Selection buttons
SPECIFICATIONS:
- Display Format: Liquid Crystal Display(LCD)
- Operate power : Battery 1.5 VDC AA x 2 with
Battery-Low indicator & protection
- Selectable display in °F or °C
- Temperature control range: Room: 40-95°F(5-35°C)
- Floor Temperature Control Range: 40-113°F(5-45°C)
- Temperature Display Range: 14-122°F(-10-50°C) with
accuracy ± 0.2°F(0.1°C). Note: No decimal indicator above 100°F
- Maximum Floor Temperature Limit.(F & AF Mode):
68-113°F(20-45°C) Default: 85°F(29°C)
- Minimum Floor Temperature Limit(F Mode only):
- 40-68°F(5-20°C) Default: 59°F(15°C)
- Note: In AF Mode, only Maximum Limit is available
- Contact Rating: 10A
- Floor limits switching differential: 4°F(2°C).
Factory Preset (not user adjustable).
- Freeze protection: factory preset. In effect when
thermostat is OFF by Power Button.
- A & AF Mode 40°F(5°C). F Mode: 50°F(10°C)
- Shortest cycle rate protection: 3 minutes (time of
delay start), effects in cool-mode only
- Switching Differential: A/AF Mode:
0.4/0.8/1.2/1.6/2°F, 0.2/0.4/0.6/0.8/1°C Default: 0.8°F/0.4°C. F Mode:
1.2/2/4/6°F, 0.6/1/2/3°C Default: 2°F/1°C
- Dimension: 125W x 90Hx 35D mm
-
Material: Non flammable plastic
D-26F
Please
click to view PDF Brochure
D-26F digital thermostat is
specifically designed for Radiant Floor Heating Systems. It is very simple to
install and operate without any programming steps. A 10 ft. auxiliary remote
sensor is provided to measure and control the slab temperature. In addition, an
ON/OFF switch can be used to turn off the relay output. Setpoint and floor
temperature or room temperature is displayed on the LCD screen with backlit.
FEATURES:
- Large LCD with backlighting for displaying Setpoint &
Floor Temperature or Room Temperature
- Slab Temperature Control for Radiant Floor Heating
Systems
- Low Voltage (24 VAC) System
- Reliable Digital Electronic Accuracy
- No Leveling Required
- Contains NO Mercury, environmentally safe
- Only 2 wires needed to power thermostat, no need to
change battery in the future
- Selectable display in °F or °C
- EEPROM for setting backup
- ON/OFF switch to shut off relay output
- Built-in Digital Control System
- Supplied with 10ft. floor sensor
SPECIFICATIONS:
- Display Format: Liquid
Crystal Display(LCD) with Backlighting
- Floor Temperature
Control Range: 41-113°F(5-45°C)
- Temperature Display
Range: 32-140°F(0-60°C)
- Contact Rating: 16A
- Power Supply: 24 Vac,
50-60Hz
- Sampling Rate: 1 Minute
- Accuracy: ±1°F
- Switching Differential:
0.5/1.0/1.5/2.0 °F/°C
- Dimension: 91.5 x 80.3 x
30 mm
- Resolution: 0.1°F
PROGRAMMABLE DIGITAL THERMOSTATS: D-500: FOR HEATING AND
COOLING D502F: FOR RADIANT FLOOR HEATING
D-500/D502F
Please
click to view PDF Brochure
Azel Technologies introduces 500 series electronic
programmable thermostat that utilizes the lastest digital technologies for
residential and light commercial systems. D-500 is designed for 24 Vac
single-stage heating and cooling systems. D-502F is designed to control the
floor temperature in Radiant Floor Heating Systems.
The 500 series can accurately control the temperature within one degree.
Reliable permanent memory retains the programmed settings in the event of a
power failure. In addition, the large, easy to read LCD display with backlit
makes the thermostat easy to operate and simple to program.
The 500 series programmable thermostat delivers maximum comfort and energy
savings by automatically changing to the preset temperature for various times of
the day The energy use and costs can be reduced according to the program heat
and cool times as much as 33%. This programmable thermostat is better for the
environment, since using less energy helps reduce greenhouse gas emissions
associated with energy production.
The Azel digital thermostat with its appealing design will allow you to replace
inaccurate, old fashioned thermostats with the new accurate and easy to read 500
series.
All Azel thermostats are backed by reputation for quality and reliability.
FEATURES:
- Large temperature
display screen with backlit for quick easy readability
- Reliable Digital
Electronic Accuracy
- Attractive styling
complements any decor
- Separate schedules for
weekdays and weekends (5-2 day programming) or 7 day by factory preset
- 6/4 Program
period(ON/OFF period) per day by factory preset
- Preprogrammed with a
typical energy saving set-up
- Vacation hold
- Temporary bypass unit
next program
- Comfort override by
holding the new setting for required hours
- Permanent hold of new
temperature setting without programming
- EEPROM Battery-free
Memory backup means no re-programming your schedule after power outage
- Purge: Fan 90 seconds
delay-off for use of residue energy in pipe
- Display in °F or °C for
added model flexibility
- Selectable 12H/24H
Format
- Optional remote sensor
for distant temperature sensing and control
- Auto-Change-Over between
Heat and Cool modes
- Copy function for
programs setting
- Remote ON/OFF control
for commercial building
- Contains NO Mercury
- No Leveling Required
- Only 2 wires needed to
power thermostat, no need to change battery in the future
- Ease-of-use means fewer
homeowner questions and increased homeowner satisfaction
- Easy installation, setup
and system checkout saves time and increases installer productivity
- Save energy cost up to
33%
- D-502F is supplied with
remote sensor probe for floor temperature control
SPECIFICATIONS:
D-500
- Display Format: Liquid Crystal Display(LCD) with backlit
- Contact Rating: 7.5A
- System: Cool-Off-Heat-Auto (changeover)
- Fan Control: On/Auto
- Temperature Display Range: 32-122°F(0-50°C)
- Temperature Control Range: Heat: 41°F to 95°F(5°C to
35°C) & Cool: 43°F to 97°F(6°C to 36°C)
- Remote control Cut-off of Heat/Cool/Fan output
- Accuracy: ±1°F
- Power Supply: 24 Vac, 50-60Hz
- Switching Differential: 1-2°F(0.5-1.0°C)
- Dimension: 138x 110 x 32 mm
D-502F: Radiant Floor Heating Thermostat (Floor Sensing Thermostat)
- Display Format: Liquid Crystal Display(LCD) with backlit
- Floor Temperature Control Range: 41-113°F(5-45°C)
- Temperature Display Range: 32-140°F(0-60°C)
- Contact Rating: 16A
- Control Floor Temperature in Radiant Floor Heating System
- Accuracy: ±1°F
- Power Supply: 24 Vac, 50-60Hz
- Switching Differential: 1-2°F(0.5-1.0°C)
- Dimension: 138x 110 x 32 mm
|
| |
DST-932PR SOLAR DIFFERENTIAL CONTROL
Please
click to view PDF Brochure
Please
click to view PDF Instructions
The DST-932 differential
temperature controller is designed for the Solar Heating Systems. The
DST-932 switches on a pump in order to transfer heat from solar
collector to a storage tank. The controller reads the temperatures of
the storage tank (T1) and of the collector (T2), when this differential
temperature (T2-T1) is higher than a set value (dt), it will switch on
the pump. It is possible to limit the maximum temperature of the storage
tank and also activate a freeze protection function. By switching to
manual mode it allows the test of the heating system by turning the pump
ON or OFF. A universal sensor P-01 or P-02(higher temperature range) is
supplied with the control. This solid state temperature sensor probe can
be extended up to 500 feet.
DST-932 is
designed to handle most differential temperature control functions for
operation of solar heating, swimming pool heating, domestic water
heating, and sophisticated space heating and cooling etc.
FEATURES:

- Reliable Digital Electronic Accuracy
- LED indicates output relay status
- Easy-to-Read Digital Display which displays
sensor and functional status. It also allows precise differential
temperature settings
- Simple programming of differential setpoint
temperature and (hysteresis) differential. Setpoint can be adjusted
easily without going into programming mode.
- A tighter differential can be achieved (eg. 1F
or 1C) than conventional electromechanical controls
- Anti-Freeze protection
- Over Heat Protection
- Anti-Short Cycle Delay to ensure the output
relay remains off for up to 254 secs. This would avoid unnecessary
hard start and equipment wear
- User selectable Celsius or Fahrenheit
scales
- Lockout switch to prevent tempering by
unauthorized personnel
- Two universal sensors P-01/P-02 are
supplied with the control. This solid state temperature sensor probe
can be extended up to 500 feet.
Easy installation
SPECIFICATIONS:
-
DISPLAY: 3 digit, 13.2 mm, high intensity green
- INPUTS: two NTC sensors or two PTC sensors
- MEASURING RANGE: -55 … +302 °F for PTC
probe
-39 … +248 °F for NTC probe
- ACCURACY AT 25°C: ±1 °F + 1 digit
- RESOLUTION: 0.2 or 2 °F
- OUTPUTS: 1 spdt 250Vac 16A max resistive (1hp)
- POWER SUPPLY: 115 Vac ±10% 50/60Hz
- Differential Setpoint range: 0.8 to 50°F
- Differential Setpoint Hysteresis(differential):
0.8 to 17.9°F
- Anti-Cycling Delay: 0 to 254 sec.
- Anti-Freeze protection: 0.3 to 50.0°F
- Anti-Freeze hysteresis(differential): 0.8 to
17.9°F
- Over Heat Protection: 32.1 to
228°F
- Over Heat Hysteresis(differential): 0.8 to
17.9°F
- Output: 1 on a SPDT 16 A 250 Vac relay
- Resolution: 1°C (1°F)
- Accuracy: ± 1°F
- Display: LED, 3 digits, 12.5 mm high
- Data storing: on EEPROM non-volatile memory
- Operating temperature: 23 to 149 °F (-5 to +65
°C)
- Relative humidity: 20 to 85 % (not condensing)
- Housing: self-extinguish UL94V0 ABS plastics,
white colour
- Size: frontal 45 x 71 mm; depth 58 mm (4 DIN
modules)
- Mounting: DIN rail for panel boards
- Power supply: 110VAC, 50/60Hz
|Home|
|About|
|Products| |Inquiry|
Order Online|
Hydronic Heating|
Copyright 2010. Azel
Technologies Inc.. All rights reserved
|
|  |